Technical data
72
75 min.
68 +0,7

Error messages

6.1 Dimensions and cutout size

Sealing screw
10
Cutout
68 + 0.7 x 68 + 0.7 mm

6.2 Default settings

The following parameters are programmed into the counter by the
factory prior to delivery:
Preset value, main counter P1
Preset value, main counter P2
Preset value, secondary counter B1
Secondary counter multiplier
Display
Pulse signal time
main/secondary counters
Counting mode
Preset change
Input function, secondary counter
Counting frequency,
secondary counter
6.3 Error messages
and
:
Error messages
key.
105
100
Packing
1-6
7
100
1000
10
1
Depending on the model with
either 2 or 3 DP
0.25s
1 (step preset)
the new preset becomes
active after reset.
External triggering
10 kHz
:
Fault must be rectified by the factory.
Excessively fast sequences, i.e.
inadequate intervals between presets
at high counting frequency.
and
can be cleared with the
NE215
23