Baumer SCATEC-2 FLDK 110 Series User Manual - Page 8
Browse online or download pdf User Manual for Cash Counter Baumer SCATEC-2 FLDK 110 Series. Baumer SCATEC-2 FLDK 110 Series 18 pages. Laser copy counter
Also for Baumer SCATEC-2 FLDK 110 Series: User Manual (35 pages)
DIP-switch settings:
The effects of the various DIP-switch settings are
described in Section 9 Instructions for use below
Do remount the cover after having set the
o
DIP-switch to avoid intrusion of dust
FLDK 110x1003/Sxx
FLDK 110x1005/Sxx
DIP-
Parameter
Setting
switch
off / off
Output pulse
off / on
1 / 2
length
on / off
on / on
False pulse
off
3
suppression
on
on
Sensitivity
4
off
Factory settings
Manual SCATEC-2
Version 2011-05
9
Instructions for use
9.1
Output pulse length and maximum counting rate
On the one hand, the duration of an output pulse must be long enough so that the customer's control
system can process it. On the other hand, the length of the output pulse limits the maximum counting
rate. Because output pulses must not overlap, the interval between edges must be at least as long as
one output pulse length. If the interval is shorter, then this edge will be suppressed meaning that the
edge will not initiate an output pulse.
The following figure illustrates how every other edge is suppressed because of a too long of an output
pulse length.
on
off
high
low
high
low
Manual SCATEC-2
Version 2011-05
Factory setting
FLDK 110x1006/Sxx
Value
Parameter
5 ms
Running
10 ms
direction
15 ms
Output pulse
20 ms
length
inactive
False pulse
Active
suppression
reduced
maximum
Sensitivity
15
www.baumer.com
Scatec-2
a
a
p
p
time
16
www.baumer.com
DIP-
Setting
Value
switch
off
leading
1
on
trailing
off
5 ms
2
on
10 ms
off
inactive
3
on
active
on
reduced
4
off
maximum
Baumer Electric AG
Frauenfeld, Switzerland
amber edge-LED
output pulse
pulse length p < interval a
output pulse
pulse length p > interval a
some edges are suppressed!
Baumer Electric AG
Frauenfeld, Switzerland