Failure to set the vehicle emergency
brake and chock wheels before
performing service can cause severe
personal injury or property damage
Hazardous
machinery can
cause serious
personal injury.
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury or property damage.
Hazardous pressure
can cause serious
personal injury or
property damage
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.
TECHNICAL DATA
Torque required
@50 psi (3.4 bar)
@100 psi (6.9 bar)
Maximum Operating
Temperature
Maximum Pump Speed
Maximum Differential
Pressure
Maximum Working
Pressure
•
Technical Data is for standard materials of
construction. Consult Blackmer Material Specs for
optional materials of construction.
•
These pumps are listed by Underwriters' Laboratories
for liquefied petroleum gas and NH
SAFETY DATA
PUMP DATA
34 lbs ft (46 Nm)
60 lbs / ft (811 Nm)
240°F (115°C)
870 RPM
125 PSI (8.6 Bar)
350 PSI (24.1 Bar)
service.
3
501-D00
Failure to relieve system pressure prior
to performing pump service can cause
serious personal injury or property
damage. Systems with meters will still
be pressurized even after the hose is
Hazardous pressure
emptied
can cause serious
personal injury or
property damage
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Do not operate
without guard
in place
If pumping hazardous or toxic fluids,
system must be flushed and
decontaminated, inside and out, prior to
performing service or maintenance
Hazardous or toxic
fluids can cause
serious injury.
INITIAL PUMP START UP INFORMATION
Model No.: ____________________________________
Serial No.: ____________________________________
ID No.: _______________________________________
Date of Installation: ____________________________
Inlet Gauge Reading: ___________________________
Discharge Gauge Reading: ______________________
Flow Rate: ____________________________________
Page 2/12