Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Installation And Operating Instructions Manual
7.2

Klemmenkasten HOG 10

7.2.1
Beschreibung der Anschlüsse
+UB; +
; ; GND; 0V
;
K1; A; A+
K1; A; A-
K2; B; B+
K2; B; B-
K0; C; R; R+
K0; C; R; R-
7.2.2

Ausgangssignale

Signalfolge bei positiver
Drehrichtung, siehe Abschnitt 6.
Sequence for positive rotating
direction, see section 6.
MB097.3 - 11070460
Betriebsspannung (für den Drehgeber)
Voltage supply (for the encoder)
Masseanschluss (für die Signale)
Ground (for the signals)
Erdungsanschluss (Gehäuse)
Earth ground (chassis)
Ausgangssignal Kanal 1
Output signal channel 1
Ausgangssignal Kanal 1 invertiert
Output signal channel 1 inverted
Ausgangssignal Kanal 2 (90° versetzt zu Kanal 1)
Output signal channel 2 (offset by 90° to channel 1)
Ausgangssignal Kanal 2 (90° versetzt zu Kanal 1) invertiert
Output signal channel 2 (offset by 90° to channel 1) inverted
Nullimpuls (Referenzsignal)
Zero pulse (reference signal)
Nullimpuls (Referenzsignal) invertiert
Zero pulse (reference signal) inverted
Baumer_HMG11-HOG10_II_DE-EN (16A2)
Elektrischer Anschluss / Electrical connection
7.2

Terminal box HOG 10

7.2.1

Terminal significance

7.2.2

Output signals

K1
K1
K2
K2
K0
K0
90°
7
22