Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Installation And Operating Instructions Manual
7.2.4

Klemmenbelegung

Max. 1,5 mm
2
Max. AWG 16
Betriebsspannung nicht auf Ausgän-
ge legen! Zerstörungsgefahr!
Spannungsabfälle in langen Leitungen
berücksichtigen (Ein- und Ausgänge).
7.3
Sensorkabel HEK 8 (Zubehör)
Es wird empfohlen, das Baumer Hübner
Sensorkabel HEK 8 zu verwenden oder
ersatzweise ein geschirmtes, paarig ver-
seiltes Kabel. Das Kabel sollte in einem
Stück und getrennt von Motorkabeln ver-
legt werden.
Kabelabschluss:
HOG 10 - HTL, HMG 11:
1 ... 3 kΩ
HOG 10 - TTL:
120 Ω
Rot/Red = +UB
Blau/Blue =
Weiß/White = K1 (A)
Braun/Brown = K1 (A)
Grün/Green = K2 (B)
Gelb/Yellow = K2 (B)
Grau/Grey = K0
Rosa/Pink = K0
Schwarz/Black = ---
Violett/Violet = ---
MB097.3 - 11070460
K0
K0
K2
K2
K1
K1
+UB
(GND)
Baumer_HMG11-HOG10_II_DE-EN (16A2)
Elektrischer Anschluss / Electrical connection
7.2.4

Terminal assignment

Ansicht Z
Anschlussklemmen,
siehe Abschnitt 7.2.3.3.
View Z
Connecting terminal,
see section 7.2.3.3.
Zwischen
und
besteht keine Verbindung.
There is no connection between
Do not connect voltage supply to
outputs! Danger of damage!
Please, beware of possible voltage drop
in long cable leads (inputs and outputs).
7.3

Sensor cable HEK 8 (accessory)

Baumer Hübner sensor cable HEK 8 is
recommended. As a substitute a shielded
twisted pair cable should be used. Con-
tinuous wiring without any splices or cou-
plings should be used. Separate signal
cables from power cables.
Cable terminating resistance:
HOG 10 - HTL, HMG 11:
1 ... 3 kΩ
HOG 10 - TTL:
120 Ω
Aderendhülsen benutzen.
Use core-end ferrules.
Kabelschirm
Cable shield
7
and
.
26