Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions - Page 8

Browse online or download pdf Mounting And Operating Instructions for Industrial Equipment Baumer HUBNER BERLIN HOG 10. Baumer HUBNER BERLIN HOG 10 40 pages. Incremental encoder with connecting cable ölfle
Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
3
Vorbereitung / Preparation
3

Vorbereitung

3.1
Lieferumfang Gerät
1)
12
6
7
8
5
4
11
Gehäuse HOG 10
1
Gehäuse ESL
2
Einseitig offene Hohlwelle oder Konuswelle
3
mit Schlüsselfläche SW 13 mm
Spannelement
4
(nur bei einseitig offener Hohlwelle)
Stützblech für Drehmomentstütze
5
Sechskantschraube M6x18 mm, ISO 4017
6
Scheibe B6, ISO 7090
7
Selbstsichernde Mutter M6, ISO 10511
8
Abdeckhaube
9
Torx-Senkschraube M4x8 mm,
10
ISO 7046
Erdungsband ~230 mm lang
11
Klemmenkasten HOG 10
12
Klemmenkasten ESL
13
Option EMS: Status LED
14
siehe Abschnitt 6.1.5.
Option M: Redundante Abtastung
1)
Option EMS:
HOG
10.2
+ ESL
2)
Option M + EMS:
HOG
10.2 M
3)
5
2)
2) 3)
14
14
2
1
,
2) 3)
HOG 10
M
+ ESL
+ ESL
3

Preparation

3.1

Scope of delivery of the device

10
13
12
Housing HOG 10
1
Housing ESL
2
Blind hollow shaft or cone shaft
3
with spanner flat 13 mm a/f
Clamping element
4
(only for blind hollow shaft)
Support plate for torque arm
5
Hexagon screw M6x18 mm, ISO 4017
6
Washer B6, ISO 7090
7
Self-locking nut M6, ISO 10511
8
Cover
9
Torx countersunk-head screw M4x8 mm,
10
ISO 7046
Earthing strap, length ~230 mm
11
Terminal box HOG 10
12
Terminal box ESL
13
Option EMS: Status LED
14
see section 6.1.5.
Option M: Redundant sensing
1)
Option EMS:
HOG
2)
Option M + EMS:
3)
Baumer_HOG10-ESL-T2_II_DE-EN (20A1)
9
,
2) 3)
HOG 10
M
+ ESL
10.2
+ ESL
HOG
10.2 M
+ ESL
MB071.2T2 - 11068774
3