Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions - Page 33

Browse online or download pdf Mounting And Operating Instructions for Industrial Equipment Baumer HUBNER BERLIN HOG 10. Baumer HUBNER BERLIN HOG 10 36 pages. Incremental encoder with connecting cable ölfle
Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (28 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
11
Technical data
11.1
Technical data - electrical ratings
• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
11.2
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection EN 60529:
• Operating speed:
• Operating torque typ.:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Corrosion protection:
• Explosion protection:
• Connection:
• Weight approx.:
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
6)
MB045T1 - 11145663
9...30 VDC
5 VDC ±5 % (TTL)
≤100 mA
300...5000 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz, ≤300 kHz option
K1, K2, K0 + inverted
HTL-P (power linedriver), TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E217823
ø105 mm
ø16...20 mm (blind hollow shaft)
ø17 mm (cone shaft 1:10)
≤450 N axial, ≤600 N radial
IP66
≤6000 rpm (mechanical)
6 Ncm
340 gcm
Housing: aluminium die-cast
Shaft: stainless steel
-40...+100 °C
-25...+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6, Vibration 20 g, 10-2000 Hz
IEC 60068-2-27, Shock 300 g, 6 ms
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
II 3 G Ex ec IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
ITT Cannon plug connector
1.6 kg
2.9 kg (option G)
Baumer_HOG10-HOG10G-Cannon_T1_DE_EN_202202_MI_11145663 (22A1)
(HTL-P, TTL - version R)
6)
2
11
Technical data
30