Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions - Page 16

Browse online or download pdf Mounting And Operating Instructions for Industrial Equipment Baumer HUBNER BERLIN HOG 10. Baumer HUBNER BERLIN HOG 10 28 pages. Incremental encoder with connecting cable ölfle
Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
5
Montage / Mounting
5.5
Schritt 5 - Drehmomentstütze
Die Montage der Drehmomentstütze
sollte spielfrei erfolgen. Ein Spiel von
beispielsweise ±0,03 mm entspricht
einem Rundlauffehler des Gerätes von
0,06 mm, was zu einem großen
Winkelfehler führen kann, siehe
Abschnitt 5.6.
13
5.5
L1
Baumer_HOG10-NIRO-A_DE_EN_202209_MI_11065823 (22A2)

Step 5 - Torque arm

The torque arm should be mounted
free from clearance. A play of just
±0.03 mm, results in a runout of the
device of 0.06 mm. That may lead to a
large angle error, see section 5.6.
MB124aT1 - 11065823