Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions - Page 21

Browse online or download pdf Mounting And Operating Instructions for Industrial Equipment Baumer HUBNER BERLIN HOG 10. Baumer HUBNER BERLIN HOG 10 28 pages. Incremental encoder with connecting cable ölfle
Also for Baumer HUBNER BERLIN HOG 10: Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Installation And Operating Instructions Manual (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (40 pages), Mounting And Operating Instructions (32 pages), Mounting And Operating Instructions (36 pages), Mounting And Operating Instructions (36 pages)

Baumer HUBNER BERLIN HOG 10 Mounting And Operating Instructions
7

Elektrischer Anschluss

7.1
Beschreibung der Anschlüsse
+UB
(0V)
K1
K1
K2
K2
K0
K0
7.2

Ausgangssignale

Signalfolge bei
positiver Drehrichtung,
siehe Abschnitt 6.1 und 6.2.
Sequence for positive
rotating direction,
see section 6.1 and 6.2.
MB124aT1 - 11065823
Baumer_HOG10-NIRO-A_DE_EN_202209_MI_11065823 (22A2)
Betriebsspannung
Voltage supply
Masseanschluss
Ground
Erdungsanschluss (Gehäuse)
Earth ground (housing)
Ausgangssignal Kanal 1
Output signal channel 1
Ausgangssignal Kanal 1 invertiert
Output signal channel 1 inverted
Ausgangssignal Kanal 2 (90° versetzt zu Kanal 1)
Output signal channel 2 (offset by 90° to channel 1)
Ausgangssignal Kanal 2 invertiert
Output signal channel 2 inverted
Nullimpuls (Referenzsignal)
Zero pulse (reference signal)
Nullimpuls invertiert
Zero pulse inverted
90°
Elektrischer Anschluss / Electrical connection
7

Electrical connection

7.1

Assignment significance

7.2

Output signals

K1
K1
K2
K2
K0
K0
7
18