Baumer HUBNER BERLIN Low Harmonics HOGS 75 Mounting And Operating Instructions - Page 21

Browse online or download pdf Mounting And Operating Instructions for Industrial Equipment Baumer HUBNER BERLIN Low Harmonics HOGS 75. Baumer HUBNER BERLIN Low Harmonics HOGS 75 32 pages. Sine encoder version with support plate for a torque arm
Also for Baumer HUBNER BERLIN Low Harmonics HOGS 75: Mounting And Operating Instructions (24 pages), Installation And Operating Instructions Manual (36 pages), Installation And Operating Instructions Manual (36 pages)

Baumer HUBNER BERLIN Low Harmonics HOGS 75 Mounting And Operating Instructions
7

Elektrischer Anschluss

7.1
Beschreibung der Anschlüsse
+UB; +
; ; GND; 0V
;
K1; A; A+
K1; A; A-
K2; B; B+
K2; B; B-
K0; C; R; R+
K0; C; R; R-
xxx
7.2

Ausgangssignale

2,5 V
Signalfolge bei positiver Drehrichtung,siehe Abschnitt 6.
Sequence for positive rotating direction,see section 6.
MB175aT1 - 11173568
Betriebsspannung
Voltage supply
Masseanschluss
Ground
Erdungsanschluss (Gehäuse)
Earth ground (housing)
Ausgangssignal Kanal 1
Output signal channel 1
Ausgangssignal Kanal 1 invertiert
Output signal channel 1 inverted
Ausgangssignal Kanal 2 (90° versetzt zu Kanal 1)
Output signal channel 2 (offset by 90° to channel 1)
Ausgangssignal Kanal 2 invertiert
Output signal channel 2 inverted
Nullimpuls (Referenzsignal)
Zero pulse (reference signal)
Nullimpuls invertiert
Zero pulse inverted
Nicht benutzen
Do not use
0,5 V
K1
K1
Baumer_HOGS75K-A-T1_II_DE-EN (19A1)
Elektrischer Anschluss / Electrical connection
7

Electrical connection

7.1

Terminal significance

7.2

Output signals

360°el.
1 V
90°el.
1 V
0,4 V
[K1] -
[K1]
=
Cos
[K2] -
[K2]
=
Sin
[K0] -
[K0]
7
18