Baumer HUBNER BERLIN MHAP 400 Mounting And Operating Instructions - Page 27
Browse online or download pdf Mounting And Operating Instructions for Industrial Equipment Baumer HUBNER BERLIN MHAP 400. Baumer HUBNER BERLIN MHAP 400 28 pages. Encoder without bearings - absolute magnetic sensing
8.4
Technical data - electrical ratings (SinCos)
• Voltage supply (Signals):
• Consumption w/o load:
• Sinewave cycles per turn:
• Phase shift:
• Sensing method:
• Output signals:
• Output stage:
• Difference of SinCos amplitude:
• Harmonics typ.:
• DC offset:
• Bandwidth:
8.5
Technical data - mechanical design
• Sensor head:
• Size (flange):
• Shaft type:
• Axial tolerance:
• Radial tolerance:
• Protection DIN EN 60529:
• Operating temperature:
• Operating speed:
• Materials:
• Resistance:
• Accuracy of magnetic measure:
• Connection:
MB222 - 11105055
Baumer_MHAP400_II_DE-EN (19A2)
P...D:
4.5...30 VDC
≤300 mA
1...32768 (as ordered)
90° ±5°
Magnetic
A+, A−, B+, B−
SinCos 1 Vpp
≤20 mV
-40 dB
≤20 mV
400 kHz (-3 dB)
FPGA signal processing
ø406.8 mm
ø70...340 mm (through hollow shaft)
(as ordered)
±1 mm (wheel/head)
0.1...0.5 mm (wheel/head)
IP67 (head)
IP68 (wheel)
-20...+85 °C
≤2000 rpm
Housing sensing head: aluminium alloy
Wheel: stainless steel (1.4104)
IEC 60068-2-6
Vibration 30 g, 55-2000 Hz
IEC 60068-2-27
Shock 300 g, 2 ms
±150 "
Flange connector M23, 17-pin
Montage / Mounting
4 8
24