Amphenol Socapex RESMLAC-12EMG-F35 Hardware User Manual - Page 5
Browse online or download pdf Hardware User Manual for Switch Amphenol Socapex RESMLAC-12EMG-F35. Amphenol Socapex RESMLAC-12EMG-F35 16 pages. Ip67 rugged ethernet managed switch
Section 3
As with any electronic device, you should place the switch where it will not be subject to
Selecting a
extreme temperatures, humidity, or electromagnetic interference that exceeds the
Site
RESMLAC-12EMG-F35 profile. Specifically, the site you select should meet the following
requirements:
CAPS for
The switches are pre-equipped with caps on all ports, including power and Ethernet.
unused
connectors
and prevent from deterioration of the contacts.
The RESMLAC-12EMG-F35 Ethernet Switch can be fastened to any flat surface by
Mounting
mounting the box directly. Refer to the mechanical drawings below. Make sure to allow
enough room to route your Ethernet and power cables.
The RESMLAC-12EMG-F35 weighs 1.150 Kg and is mounted via its four # 10-32UNF
Captive Screws.
The overall external dimensions of the RESMLAC-12EMG-F35 are 178(L) x 136(W) x 47(H)
millimeters.
RESMLAC 12EMG F35 - UM
Installation
•
The ambient temperature should be between -45 to +80 degrees Celsius.
•
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards for MIL-STD-461E.
Make sure all connectors are protected with cap or sealed plug to ensure sealing
www.amphenol-socapex.com
rev. 1
Page 5/16
Tel: +33(0)4.50.89.28.00