Dover All-Flo PSG 72000-00 Installation Operation & Maintenance - Page 5

Browse online or download pdf Installation Operation & Maintenance for Controller Dover All-Flo PSG 72000-00. Dover All-Flo PSG 72000-00 9 pages. Batch controller

Dover All-Flo PSG 72000-00 Installation Operation & Maintenance

INSTALLATION

72000-00 BATCH CONTROLLER
The 72000-00 controller requires 100 volts AC (220 volts AC is also available) to power. It delivers 12 volts DC
to the pump. The appropriate 12-volt DC solenoid pump is needed to be used with this controller. This system
is programmed using the keypad on the cover and can be remotely paused or stopped using dry contact via a
Switch terminal on the circuit bord. This controller should be mounted close to pump in a dry and safe place.
The enclosure is NEMA 4X, but All-Flo advises to avoid hosing the unit.
KEYPAD FUNCTIONS
1. Selection Indicator: The LCD screen shows the
current batch or program you are running. This
will change based on which preprogrammed
batch is selected for your operation.
2. Speed: The LCD readout shows the time interval
between strokes. The stroke interval is shown
in strokes per seconds. The range for this cycle
counter is 0.1 to 3,600 Seconds/Stroke.
3. Run: This button will give the signal to the
solenoid on the pump to start the application you
have selected.
4. Batch: This button cycles through the preset
batch operations saved on the cycle counter.
Hitting this button should change the readout of
the LCD screen shown at point 1.
5. Constant: This button is used to set the pump to
run constantly. To achieve this, press this button
and then the run button shown as point 3.
6. Pause: This button will momentarily stop the
operation that is being run. This will not remove
the current count of the batch operation.
7. Set: This button is used to program the batch
operations that are to be saved on the cycle
counter. Hitting this button multiple times
will cycle through the batch's programable
information like speed, duration, and time
between batches.
8. Stop: This button will stop the operation that is
being run. Hitting this button during the batch
process will not allow the batching process to be
continued from the point the stop button was hit.
The batch operation would need to start from the
beginning.
9. Up/Down: These buttons are used when setting
the preset batch information.
ALF-14020-E-02
5
3
SECTION
All-Flo