Dovre 500cc Installation And Operation Manual - Page 6
Browse online or download pdf Installation And Operation Manual for Wood stove Dovre 500cc. Dovre 500cc 19 pages.
-4-
CHIMNEYS
THE VENTING SYSTEM CONSISTS OF A CHIMNEY CONNECTOR AND A CHIMNEY. THESE GET EXTREMELY
HOT DURING USE. TEMPERATURES INSIDE THE CHIMNEY MAY EXCEED 2000 DEGREES IN THE EVENT
OF A CREOSOTE FIRE.
TO PROTECT AGAINST THE POSSIBILITY OF A HOUSE FIRE, THE CHIMNEY
CONNECTOR AND CHIMNEY MUST BE PROPERLY INSTALLED AND MAINTAINED.
A THIMBLE MUST BE
USED WHEN A CONNECTION IS MADE THROUGH A COMBUSTIBLE WALL TO A CHIMNEY.
A CHIMNEY
SUPPORT PACKAGE MUST BE USED WHEN A CONNECTION IS MADE THROUGH THE CEILING TO A
PRE-FABRICATED
CHIMNEY.
THESE ACCESSORIES ARE ABSOLUTELY NECESSARY TO PROVIDE SAFE
CLEARANCES TO COMBUSTIBLE WALL AND CEILING MATERIAl.
OF COURSf
I
THE CHIMNEY IS RESPONSIBLE FOR VENTING OUT SMOKE AND GASES. THIS IS DONE BY
CHIMNEY DRAFT.
DRAFT IS A FUNCTION OF THE HEIGHT AND DIAMETER OF A CHIMNEY FLUE
COMBINED WITH FLUE TEMPERATURE VERSUS OUTSIDE AIR TEMPERATURE. A WARM CHIMNEY WILL
DRAW BETTER ON A COLD DAY THAN ON A MILD DAY. THE AMOUNT OF DRAFT IN YOUR CHIMNEY MAY
ALSO BE DEPENDENT ON LOCAL GEOGRAPHY, NEARBY OBSTRUCTIONS, AND OTHER FACTORS.
THE HORIZON MINIMUM DRAFT REQUIREMENT IS -.055
WATER COLUMN INCHES. TOO MUCH DRAFT
MAY CAUSE EXCESSIVE TEMPERATURE IN THE HEATER AND MAY DAMAGE THE CATALYTIC COMBUSTOR.
INADWUATE DRAFT MAY CAUSE BACKPUFFING INTO THE ROOM AND "PLUGGING" OF THE CHIMNEY OR
THE CATALYST.
1
HE NFPA, AND MOST LOCAL CODES, STATE THAT
CHIMNEYS MUST BE THE REQUIRED HEIGHT ABOVE
THE ROOF OR OTHER OBSTRUCTIONS FOR SAFETY
AND FOR PROPER DRAFT OPERATION.
THE
REQUIREMENT IS THAT THE CHIMNEY MUST BE AT
I.fAST 3 FEET HIGHER THAN THE HIGHEST POINT
WHERE IT PASSES THROUGH THE ROOF AND AT
LEAST 2 FEET HIGHER THAN THE HIGHEST PART OF
THE ROOF OR STRUCTURE THAT IS WITHIN 10 FEET
OF THE CHIMNEY, MEASURED HORIZONTALLY.
EXISTING t1ASONRY CHIMNEYS MAY BE APPROPRIATE FOR YOUR UNIT IF THE CHIMNEY FLUE DOES NOT
SERVE ANY OTHER APPLIANCE. A DOVRE UNIT REQUIRES A MINIMUM 6
U
DIAMETER FLUE. IF YOU ARE
PLANNING TO USE AN EXISTING CHIMNEY, FIRST HAVE IT CLEANED AND INSPECTED BY A QUAliFIED
PROFESSIONAL TO INSURE THAT IT IS ACCEPTABLE TO THE LOCAL AUTHORITIES AND IS IN OOOD
CONDITION.
DO NOT CONNECT YOUR UNIT TO AN UNLINED CHIMNEY.
FLUE GASES COULD
PENETRATE INTO THE HOUSE
I
AND THERE IS A DANGER OF EXPOSING NEARBY WOODEN MEMBERS OF
THE HOUSE TO HIGH TEMPERATURE, DUE TO POSSIBLE DRIED AND CRACKED MORTAR JOINTS.
~RNIN6
STATEMENT:
THE CHIMNEY FLUE CONNECTED TO A DOVRE UNIT MUST
NOT BE USED TO VENT ANY OTHER COAL, GAS, OIL, OR WOODBURNING APPLIANCE, AS
THIS MAY ALLOW HARMFUL ~ES
INTO THE HOUSEHOLD AIR SUPPLY.
-IF YOUR CHIMNEY NEEDS REPAIR, CALL A CHIMNEY MASON. SHOULD YOU DECIDE TO BUILD A NEW
MASONRY CHIMNEY, CALL A QUALIFIED MASON AND BE SURE IT IS BUILT TO COMPLY WITH LOCAL
CODES, OR NFPA #211.
CHIMNEY HEIGHT