Technical specifications
Refrigeration pressure data
§ Water regulating valve is factory set at 300 ±10 PSIG (2068.4 ± 69 kPA) head pressure.
§ Readings within 10% of table values should be considered normal.
Compressor data
Air-cooled
Ambient air temperature
Amperage
High-side pressure (PSIG)
Low-side pressure (PSIG)
Locked rotor amps
Condenser water usage:
Gearmotor data
Gearmotor current
Refrigeration system
Important: All service on refrigeration system must be performed in accordance with all federal, state and local laws
that pertain to the use of refrigerants. It is the responsibility of the technician to ensure that these requirements are
met.
R414 ice machine charge specifications
Model
E414 230 V, 50 Hz air-cooled
4
MC_414A, MF_414A, R290 230 V/50 Hz Ice Machines
50 F/10 C
2.25
105
18.5
230 V: 18.2A
@90 F/70F: 0.56 gal/min
230 V/50 Hz
1.3A (nominal)
3.52 oz (100 grams)
70 F/21.1 C
90 F/32.2 C
2.36
2.46
142
190
21
25
Charge
110 F/43.3C
2.57
245
27
Refrigerant type
R290