Dovre 2000CBGL Installation Instructions & Operating Manual - Page 8

Browse online or download pdf Installation Instructions & Operating Manual for Indoor Fireplace Dovre 2000CBGL. Dovre 2000CBGL 20 pages.

3.2.2. Assembly of the smoke dome and of the flue collar
The smoke dome must
be fixed to the top of
the device and attached
by means of the clamps
supplied. A ssure proper
sealing by means of the
kit or paste supplied.
It is recommended to
install the smoke dome
with its exhaust bac k-
wards. In case of proper
draft, it may be turned
up to 90° to the left or to
the right if required for
installation. In case of
lower draft, an angle of
maximum 60° is recom -
mended.
The flue collar can be
installed either horizon-
tally or vertically. Fix the
flue collar on the smoke
dome
with
2
M6x30, 2 nuts M6, and
4 collars Ø6xØ12. Assure proper sealing with kit or paste.

3.2.3. Installation of the ashtray (if applicable)

The optional ashtray is installed as follows:
Lift the plate in the middle of
the bottom brick; insert a
screwdriver into the hole to
lift the brick (if necessary, tap
the brick with a hammer to
loosen it).
Extrude the pre -cut plate from
the bottom heat shield.
Clean the sealing edge and
put the supplied rope (diam.
6 mm) in the groove; install
then the ashtray holder.
Tighten the 4 plate screws in
the ashtray holder and assure
proper sealing with kit or
paste.
You can now install the ashtray and the grid.
2000CB
bolts
KIT
8