Follett HCD1400NBT Manual - Page 5

Browse online or download pdf Manual for Ice Maker Follett HCD1400NBT. Follett HCD1400NBT 8 pages. With remote air-cooled condensing unit
Also for Follett HCD1400NBT: Installation Instructions Manual (17 pages), Manual (8 pages)

Follett HCD1400NBT Manual
Horizon
Chewblet ice icemaker
5
Remote condensing unit
Important specifier notes:
1. Provide front, back and side clearances
as shown.
2. The maximum refrigerant line run length
is 100 ft (30.5 m). Installations with up to
50 ft (15.2 m) line run require:
1000 Series – 8 lbs (4 kg) of refrigerant
1400 Series – 11 lbs (5 kg) of refrigerant
1800 Series – 11 lbs (5 kg) of refrigerant
(consult installation manual for correct
refrigerant charge if line run exceeds
50 ft (15.2 m).
3. The maximum line rise above the
evaporator is 35 ft (10.7 m). Condensing
unit above evaporator unit – 35 ft
(10.7 m) (installations with rise over 20 ft
(6.1 m) require additional suction line
s-trap at midpoint rise).
4. The evaporator can only be mounted
a maximum of 15 ft (4.6 m) above the
condensing unit.
Note: The service loop is not included
when calculating length, rise or drop in
the tubing run.
Note: To connect evaporator/icemaker to rack systems, see page 7.
Condensing unit installation specifications
38"
(97 cm)
Follett Corporation
801 Church Lane • Easton, PA 18040, USA
+1 (610) 252-7301 • Fax +1 (610) 250-0696
www.follettice.com
KaTom Restaurant Supply, Inc.
1000 series, 1400 series or 1800 series
with remote air-cooled condensing unit
Undercounter/in-cabinet mounting & ventilation
exhaust
48"
(122 cm)
Follett Europe Polska
Mokry Dwór 26C • 83-021 Wislina, Poland
+48 (58) 785-6140 • Fax +48 (58) 785-6159
www.folletteurope.com
air in
48"
(122 cm)
48"
(122 cm)
Form# 3815
5