PROGRAMMING THE MINIK10
The MiniK10 can be customized from factory default settings tailored to your needs.
ACCESSING THE PROGRAM MENU:
Press the
button and then enter the 6-digit master password. Press the
program number that you will make an adjustment to, and then press the adjustment selection.
Explanation:
0-1 Restores factory default settings:
0
1
Individual operation
0
1
One -time-use operation (locker mode for multiple users)
1
Mute operation except for warnings
0
2
Audible operation- button feedback, warnings and confirmations
1
Penalty not active
0
3
Penalty active (lock blocked for 5 minutes if wrong code entered 3 times)
1
None
0
4
None
1
Service password is not active
0
5
Service password is active
1
Closing with password is active
0
6
Automatically closing is active (for individual usage)
1
Warning of door open is not active
0
7
Warning of door open is active (beeps 8 times every 5 seconds)
1
Resetting user password is not active (if service password is active)
0
8
Resetting user password is active (if service password is active)
1
Blocking of the lock is not active (if service password is active)
0
9
Blocking of the lock is active after using service password (if it is active)
1

MASTER PASSWORD

Prg No 1-1: One -time-use operation (Locker mode with multiple users)
Prg No 2-1: Audible beeps and confirmations
Prg No 3-0: Penalty operation is not active
Prg No 4-0: No function currently assigned
Prg No 5-0: Service password is not active
Prg No 6-0: Closing with password required
Prg No 7-0: Warning of open door is not active
Prg No 8-0: Resetting user password is not active
Prg No 9-0: Blocking of the lock is not active