Amplicomms BTH 1400 User Manual

Browse online or download pdf User Manual for Headsets Amplicomms BTH 1400. Amplicomms BTH 1400 18 pages.

Remote condensing unit

Condensing unit installation specifications
Important specifier notes
1. Provide front, back, top and side clearances
as shown.
2. The maximum refrigerant line run length is
100' (30.5 m). Installations require 12 lb for
1010/1410 single phase, 12.5 lb for 1010 three
phase and 10 lb for 1410 three phase.
3. The maximum line rise above the evaporator is
35' (10.7 m). Condensing unit above evaporator
unit – 35' (10.7 m) (installations with rise over
20' (6.1 m) require additional suction line s-trap
at midpoint rise).
4. The evaporator can only be mounted a maximum
of 15' (4.6 m) above the condensing unit.
Note: The service loop is not included when
calculating length, rise or drop in the tubing run.
Note: To connect evaporator/ice machine to rack systems, see page 3.
Ice production – Horizon Elite 1010 series,
air-cooled models
Ambient air temperature F (C)
Inlet water
temperature
60 (16)
70 (21)
F (C)
50 F (10 C)
1051 (477)
978 (444)
60 F (16 C)
1037 (471)
925 (420)
70 F (21 C)
937 (425)
871 (395)
80 F (27 C)
904 (410)
839 (381)
90 F (32 C)
872 (396)
807 (366)
ENERGY STAR and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency.
Agion is a registered trademark of Sciessent LLC.
HORIZON ELITE, ICE•DEVICE, ICE MANAGER, MICRO CHEWBLET, SAFECLEAN PLUS, SANISPONGE, SYMPHONY PLUS and VISION are trademarks of Follett Products, LLC.
CHEWBLET, FOLLETT and RIDE are registered trademarks of Follett Products, LLC, registered in the US.
Follett reserves the right to change specifications at any time without obligation. Certifications may vary depending on country of origin.
Remote 1010, 1410 series ice machine
7035-202109 | © Follett Products, LLC
80 (27)
90 (32)
100 (38)
906 (411)
834 (379)
763 (346)
855 (388)
796 (361)
737 (335)
805 (366)
758 (344)
711 (323)
774 (351)
727 (330)
680 (309)
743 (337)
696 (316)
648 (294)
=
24.00"
(61.0 cm)
48.00"
(121.9 cm)
Ice production – Horizon Elite 1410 series,
air-cooled models
Inlet water
temperature
60 (16)
F (C)
50 F (10 C)
1474 (669)
60 F (16 C)
1385 (628)
70 F (21 C)
1296 (588)
80 F (27 C)
1239 (562)
90 F (32 C)
1181 (536)
801 Church Lane | Easton, PA 18040, USA
1.800.523.9361 | 1.610.252.7301 | follettice.com
36.00" (91.4 cm)
height clearance
air in
48.00"
(121.9 cm)
24.00"
(61.0 cm)
Ambient air temperature F (C)
70 (21)
80 (27)
90 (32)
1372 (623)
1269 (576)
1212 (550)
1292 (586)
1198 (544)
1148 (521)
1212 (550)
1127 (511)
1083 (492)
1155 (524)
1072 (487)
1030 (468)
1099 (499)
1017 (462)
976 (443)
100 (38)
1154 (524)
1097 (498)
1039 (472)
988 (449)
936 (425)