Follett Horizon Elite HCD1810NMS Installation Instructions Manual - Page 9
Browse online or download pdf Installation Instructions Manual for Ice Maker Follett Horizon Elite HCD1810NMS. Follett Horizon Elite HCD1810NMS 17 pages. For ice manager diverter valve
Also for Follett Horizon Elite HCD1810NMS: Quick Start Manual (8 pages), Manual (8 pages)
Connect utilities to louvered docking assembly.
• Plug must be accessible after final installation.
5.1
Water and drain
➋
➏
silicone tubing
3/4" barb x 3/4" FPT
➍
3/4" MPT x 1" slip
➎
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
➊
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
➎
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
ICE MANAGER
CAUTION
➊
➌
Minimum 8"
radius
2 ft. x 1" OD
➋
.
➌
.
➍
.
➏
remote condensing
External connections
5.2
Refrigerant
➊
• Braze supplied quick-connect lines onto
stub-ins
➊
.
5
9