Model 100A250A
2.2.2
2.2.2.8
Remote Commands (continued)
2.2.2.8.1 Power On/Off
Controls the power on/off state of the Model 100A250A.
Syntax: Px
Parameters:
Example: To turn the power on, send the following command:
P1<LF>
2.2.2.8.2 Gain Set
Sets the gain in steps of (Max Gain)/4096 W.
Syntax: Gxxxx
Parameters:
2.2.2.8.3 Reset
Resets the Model 100A250A, clearing all faults, if possible.
Syntax: R
Parameters:
Example: To clear a fault, send the following command:
R<LF>
Remote Operation (continued)
0 = power off
1 = power on
0000 = Minimum Gain
4095 = Maximum Gain
None