Follett U300R800A/W Installation Manual - Page 3
Browse online or download pdf Installation Manual for Ice Maker Follett U300R800A/W. Follett U300R800A/W 12 pages. U300/ud300 series ice and beverage dispensers
Also for Follett U300R800A/W: Operation Manual (17 pages)
Electrical specifications – 115V, 60Hz, 1 phase
• Maximum fuse size 15 amps, each circuit all models
• Equipment ground required
• Electric disconnect suggested within 10 ft (3m) of dispenser and icemaker(s)
Single-sided dispensers
U300 – dispenser 6.0 amps
U300B – dispenser 7.0 amps
U300R400A/W – dispenser 6.0 amps, icemaker 11.0 amps
U300BR400A/W – dispenser 7.0 amps, icemaker 11.0 amps
U300R800A/W – dispenser 6.0 amps, icemakers 11.0 amps each
U300BR800A/W – dispenser 7.0 amps, icemakers 11.0 amps each
Dual-sided dispensers
UD300 – dispenser 8.0 amps
UD300R400A/W – dispenser 8.0 amps, icemaker 11.0 amps
UD300R800A/W – dispenser 8.0 amps, icemakers 11.0 amps each
On all models with remote icemaker(s), black wire on icemaker control board
LINE VAC terminal must be moved to 24V terminal.
Plumbing
Caution: Do not reduce size of drain lines or tie drains together.
Dispenser
Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot slope
(6mm per 304mm run) on drain line run.
Icemaker Refer to Icemaker Installation Manual packed with icemaker for installation instructions
Note: Water disconnect within 10 ft (3m) of dispenser is suggested for auto load units.
Beverage connections
Dispenser type
Single-sided models
Dual-sided models
3/4" slip fit PVC bin drain
1" PVC slip fit drain pan drain(s)
1" PVC slip fit beverage bath drain (units with beverage cooling)
1/4" FPT water in
1/2" MPT drain
3/8" FPT condenser inlet (water-cooled condenser only)
1/2" FPT condenser drain (water-cooled condenser only)
Syrup lines
1/4" barb
Pigtail connections provided at base of dispenser
1/4" hose
Carbonator manifold
3/8" barb
3/8" hose
2
Plain water lines
1/4" barb
1/4" hose