Comdel ESC-2/FP Operator's Manual - Page 12
Browse online or download pdf Operator's Manual for Portable Generator Comdel ESC-2/FP. Comdel ESC-2/FP 17 pages. Electrostatic voltage source
G. Remote Interface Connections
Signal Pin
1
14
2
15
3
16
4
17
5
18
6
19
7
20
8
21
9
22
10
23
11
24
12
25
13
Addendum for ESC-2/FP - 2KV Systems.
Front Panel Display—Scaling:
1.
Voltage setpoint and monitor scaling: The voltage setpoint and ouput monitor displays read at full scale
as 2.00, this implies an output of 2000 volts dc from HV+ to HV- terminal. The scaling is linear throughout
its entire range. Thus, .10 represents 100vdc and .05 is 50vdc output.
2.
Current setpoint and monitor scaling: The current setpoint and I+ and I- ouput monitor displays read at
full scale as 3.0, this implies an output of 3mA dc from either HV+ to HV- terminal. The scaling is linear
throughout its entire range. Thus, .1 represents .1mA dc.
9
Certification
1.
This unit carries the ETL safety compliance mark to UL standard UL-1012.
2.
This unit is designed and labeled in compliance with CE mark certification requirements. The
manufacturer will supply a Declaration of Conformity as required.
© 2006 Comdel, Inc.
Function
Voltage set-point input, analog return
Voltage set-point input, analog positive
Current limit set-point input, analog return
Current limit set-point input, analog positive
Output voltage monitor, analog positive
Center tap terminal voltage monitor, analog positive
Positive terminal current monitor, analog positive
Negative terminal current monitor, analog positive
Monitor circuits, analog return
HV enable input, positive input
HV enable, negative input
Polarity change command, input positive
Polarity change, input negative
Discharge command, input positive
Discharge command, input negative
HV indicator output, open collector
HV indicator output, open emitter
No connection
No connection
No connection
No connection
+15Vdc
+15Vdc
Control circuit common ground
Control circuit common ground
ESC-2/FP Manual
9