Service

Latch adjustment

To adjust for proper latch engagement
1.
Loosen striker plate mounting screws (Fig. 6.1).
2. Move striker plate up or down as required and tighten screws.
3. Test operation of latch.
To adjust for proper gasket seal
1.
Loosen striker depth adjustment screw (Fig. 6.2).
2.
Adjust stop in or out and tighten screws.
3.
Test operation of latch.

Door gasket replacement

1.
Remove existing gasket from mounting track.
2. Verify mounting track is free of any remaining gasket material.
3. Align new gasket with mounting track and press firmly in place.
4. Open and close door, checking for proper gasket seal without
pinching against freezer.
5. Adjust latch and or striker as necessary for proper door closure.

Slide-out compressor tray

Follett's slide-out compressor tray allows technicians to partially slide the
condensing unit from the freezer back without cutting refrigerant lines.
1.
Remove rear panel (Fig. 7.1).
2. Remove two bolts securing condensing unit to freezer base (Fig. 7.2).
3. Gently slide condensing unit out (Fig. 7.3).
Note: Do not put undue strain on the refrigerant lines.
10
Service
Fig. 6
1
2
Fig. 7
2
3
FZR PL Series 00939132R00