Follett 15 Series Installation Manual - Page 5

Browse online or download pdf Installation Manual for Dispenser Follett 15 Series. Follett 15 Series 20 pages. Ice and water dispenser

Follett 15 Series Installation Manual
Water
WARNING!
Connect to potable water supply only.
§ Water Mineral Content:
– TDS: greater than 5 ppm (mg/l) but less than 400 ppm (mg/l)
– Hardness: Less than 200 mg/l (12 gpg)
§ Not recommended for use with softened water
§ Ingress Protection (IP) rating: IPX0 (no protection)
Clearances
§
CI/FS Models:
UD/UC Models: 3" (7.6 cm) behind dispenser for electrical and optional drain connection. 6" (153 mm) in
§
Electrical
115 V
§ 115 V, 60 Hz, 1 phase, 5A, maximum fuse 15A
§ Connect to dedicated 15A circuit, fuse or breaker
§ Must be grounded - requires 3-prong outlet. Do not remove ground.
230 V and 220 V
§ 230 V, 50 Hz, 1 phase, 5.5A or 220 V, 60 Hz, 1 phase, 5.5A
§ Connect to a dedicated circuit
§ Equipment ground required
§ Cord provided on ice machine
§ Replacement cord instructions, type IEC 60320-C13 attachment. If the supply cord is damaged, it must be
replaced by a special cord or assembly available from the manufacturer or its service agent.
Refrigeration
WARNING!
Do not damage the refrigerant circuit. Refrigerant can cause personal injury and/or damage dispenser.
§ Refrigerant
– 115 V: R134a – 5.0 ounces (142 grams)
– 230 V/220V: R134a – 7.2 ounces (204 grams)
Heat Rejection
§ 1700 BTU/hr (498 W)
3" (7.6 cm) behind and on each side of dispenser for electrical and connection and
ventilation
front of dispenser for ventilation.
Dispenser and Ice Machine - 115 V, 230 V, 220 V
5