DPA 4012 User Manual - Page 6
Browse online or download pdf User Manual for Microphone DPA 4012. DPA 4012 14 pages. Cardioid
microphones
Also for DPA 4012: User Manual (16 pages), User Manual (16 pages), User Manual (16 pages)
User's Manual
Full Specifications
Cartridge type: Pre-polarized condenser B&K Type MM0056
Principle of operation: Pressure gradient
Power Supply: 4011: Phantom P48
Frequency range: On-axis: 40Hz - 20kHz ±2dB
Phase response: Phase matching between any two microphones: ±15°
Directional characteristics: Cardioid
Sensitivity: 4011: Nominally 10mV/Pa; -40dB re. 1V/Pa unloaded (at 1kHz)
4012: Nominally 9mV/Pa; -41dB re. 1V/Pa unloaded (at 1kHz)
Equivalent noise level A-weighted: Typ. 19dB(A) re. 20µPa (max. 20dB(A))
Equivalent noise level CCIR 468-1: 4011: Typ. 25dB (correct with the attenuator
Max SPL: 4011: 158dB SPL peak before clipping (attenuator set to either
4012: 168dB SPL peak
4012: with PCC4000: 155dB peak
Total Harmonic Distortion: 110 dB SPL peak (<0.5% THD)
Preamplifier:
Frequency range: 4012: 20Hz to 50kHz ±0,2dB, 5Hz to 150kHz -3dB
Output impedance: <220 Ohm
Cable drive capability: 4011: Up to 100m
4012: HMA4000 Two-channel High-Voltage Microphone
Amplifier - 130V or PCC4000 Passive Connection
Converter for P48
(100Hz to 20kHz)
0dB or -20dB)
116 dB SPL peak (<1% THD)
4011: 20Hz to 40kHz -3dB (loaded with 2x10 kOhm//
10nF - equivalent to 100m cable)
4012: With HMA4000: Up to 300m
4012: With PCC4000: <100m
in 0dB or -20dB setting)
4012: Typ. 25dB
5