°C / °F
Press the
key to change from Celsius (°C) to Fahrenheit (°F) temperature
scale.
This setting can not be changed when in the HOLD mode. The TMD-10 will
auto save the temperature scale setting during shutdown.

MAX, MIN and AVg

button to start the recording of the maximum, minimum,
Press the
and average of all readings after the function is enabled. Pressing the
button steps the top reading through the MAX, MIN, and AVG values. Press
the
button for > 1 second to disable the function.
The MAX, MIN or AVG reading is shown on the top display and the actual
reading is shown on the bottom display for T1.
To use MAX, MIN, and AVG for T2, disable MAX, MIN, and AVG and press and

hold

key > 1 sec to swap T2 to the top display and T1 to bottom display.
Press
button again to activate the function.
If the TMD-10 turns off because of Auto Power Off, the recorded values will
be saved for use when the meter is re-energized.

k / J

Press
key to switch T1 from type K to type J thermocouple for the top
display.
Press and hold
bottom display.
Press
key to switch T2 from type K to type J.
Press and hold
bottom display.
� This setting cannot be changed if in HoLD, MAX/MIN, T1-T2 or REL
modes.
The TMD-10 will auto save the thermocouple type setting during shutdown.
HoLD
Press the
key to freeze the LCD displays. Press the HOLD key again to
return to normal operation. When the
keys are disabled except for power � key.

REL

Relative mode allows the user to offset the subsequent meter measurements
with the top display reading as the reference value.
Press the
button to enable the Relative function for the T1 thermo-
couple. The top display will reset to 0.0 (reference value) and subsequently
readings display the difference between the reference value and the actual
reading. The actual reading is shown on the bottom display. Press the
button to disable the Relative function.
key > 1 sec to swap T2 to the top display and T1 to
key > 1 sec to swap T1 to the top display and T2 to
function is enabled, all function
6