REAR PANEL VIEW
No.
Title
1
AC POWER CONNECTOR
2
RS-422
3
GPIB
4
DEBUG
5
USB
6
ETHERNET
7
INTERLOCK
8
GND
9
50Ω OUTPUT
10
Cooling FAN
AC Power Input 100 ~ 240VAC, 47/63Hz, IEC60320-14 Connector.
System RS-422 Communication / Gating Signal Female 9-Pin D-Sub Connector.
P1 TX-
P6 N/C
P2 TX+
P7 N/C
P3 RX+
P8 N/C
P4 RX-
P9 N/C
P5 GND (RS-422)
IEEE-488 GPIB Interface Connector, Female.
System Controller Debugging Female Connector.
Port access requires factory authorization
USB Communication Connector, Type A Female.
Ethernet Communication Female Connector, RJ-45.
For a system with a digital controller option – DO NOT USE OR
CONNECT a PoE enabled ethernet switch to a system. Our digital
controller does not support PoE connection and will cause permanent
damages to a controller unit.
BNC Female, Safety Interlock Connector
Interlock Close Circuit : Normal operation
Interlock Open Circuit : RF Off operation
Frame Ground.
N Female, 50Ω OUTPUT Connector.
System Outlet Cooling FAN.
Function
8 |
P a g e
- Ver. 1.0 – 11-22