Follett Symphony Plus 12CI414A Installation Manual - Page 3
Browse online or download pdf Installation Manual for Dispenser Follett Symphony Plus 12CI414A. Follett Symphony Plus 12CI414A 17 pages. Ice and water dispensers

Specifications
16.00"
(40.7 cm)
Front View
Electrical
§ 230 V, 50 Hz, 1 phase, 5.5A
§ Connect to a dedicated circuit.
Ambient
Air temp*
Water temp
†
Water pressure
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
†
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
Dispenser drain
Water inlet
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
§ 6" (15.3 cm) on right side of dispenser, 6" (15.3 cm) at top for ventilation and 12" (30.5 cm) at top recommended
for service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
§ 144 lb (65 kg)
4.00"
(10.2 cm)
23.5"
(59.7 cm)
Side View
100 F/38 C Max.
90 F/32 C Max.
70 psi/5 Bar Max.
22.625"
(57.5 cm)
32.00"
(82.6 cm)
18.00"
(45.8 cm)
50 F/10 C Min. Best performance below 80 F (27 C)
45 F/4 C Min. Best performance below 70 F (21 C)
10 psi/0.7 Bar Min.
12CI414A
3/4" MPT
3/8" FNPT
E12CI414A R290, 230 V 50 Hz
air exhaust
3/4" MPT drain
3/8" FPT
water inlet
air
intake
power cord
Rear View
3