Follett Symphony Plus 12CI414A Installation Manual - Page 3

Browse online or download pdf Installation Manual for Dispenser Follett Symphony Plus 12CI414A. Follett Symphony Plus 12CI414A 17 pages. Ice and water dispensers

Follett Symphony Plus 12CI414A Installation Manual

Specifications

16.00"
(40.7 cm)
Front View
Electrical
§ 230 V, 50 Hz, 1 phase, 5.5A
§ Connect to a dedicated circuit.
Ambient
Air temp*
Water temp
Water pressure
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine reservoir.
Plumbing
Dispenser drain
Water inlet
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.
Ventilation clearances
§ 6" (15.3 cm) on right side of dispenser, 6" (15.3 cm) at top for ventilation and 12" (30.5 cm) at top recommended
for service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
§ 144 lb (65 kg)
4.00"
(10.2 cm)
23.5"
(59.7 cm)
Side View
100 F/38 C Max.
90 F/32 C Max.
70 psi/5 Bar Max.
22.625"
(57.5 cm)
32.00"
(82.6 cm)
18.00"
(45.8 cm)
50 F/10 C Min. Best performance below 80 F (27 C)
45 F/4 C Min. Best performance below 70 F (21 C)
10 psi/0.7 Bar Min.
12CI414A
3/4" MPT
3/8" FNPT
E12CI414A R290, 230 V 50 Hz
air exhaust
3/4" MPT drain
3/8" FPT
water inlet
air
intake
power cord
Rear View
3