Manual setting of the stroke using a remote control
1) Store the remote control to the START (see Chapter 7).
2) Close the gate and press once both buttons LEARN and WORK; led DL8 starts flashing quickly.
3) Hereinafter follow up the setting as reported on topic no. 2 Chapter 11 pressing remote control button just stored instead of WORK button.
13
etting of the automatic shutting time
S
1) Close the gate and press once button LEARN.; led DL8 starts flashing.
2) Press once the button BREAK; led DL8 starts flashing quickly, the control panel is counting the automatic shutting time.
3) To stop the counting, press again the button BREAK; led DL8 switches off. Maximum time to set is 120 seconds.
To disable the automatic shutting:
1) Press once the button LEARN.
2) Press twicw quickly the button BREAK.
14
How to get separate inputs OPEN and CLOSE
How to turn START into CLOSE only:
Cut off power supply, keep pressed both buttons LEARN and BREAK and give power back keeping the buttons pressed down; led DL8 flashes to
confirm the good success of the operation, now release the buttons.
How to turn PED into OPEN only:
Cut off power supply, keep pressed both buttons LEARN , BREAK and WORKand give power back keeping the buttons pressed down; led DL8 flashes
to confirm the good success of the operation, now release the buttons.
How to go back to STARD and PED as sequential/standard inputs:
Cut off power supply, keep pressed both buttons LEARN and WORK and give power back keeping the buttons pressed down; led DL8 flashes to
confirm the good success of the operation, now release the buttons.
P.S: The control panel CLIMA24 is delivered from the factory with inputs START and PED as sequential/standard inputs.
15
Additional important information
1) CLIMA24 control panel con work with or without back up battery. In any case, it uploads and keeps leaded the back up batery athe same time;
approx. 24h are necessary to re‐charge the batery for completely. In case the control panel works only with the back up batery, the photocells start
working only in presence of a START signal; moreover, if a fashing light or a door indicator are wired on the panel, the frequency of the blinks will
slow down to save energy. If the back up batery has almost run out, the control panel remains powered but when the batery runs out completely,
the panel doesn't accept the START signal; the panel needs 140 mA as normal working that is equivalent to 50 hours working with a back up batery
of 7Ah and in Stand‐By 38 mA that is equivalent to 184 hours with a back up batery of 7Ah.
2) This control panel is provided with an anti crashing system that recognises the obstacles. This feature can be adjusted by the Trimmer AMP.
When the gate meets an obstacle while opening, it stops and reverses the stroke for about 1 sec. and after 30 sec. it closes automatically. When the
gate meets an obstacle while closing, it stops and re‐open completely. In case the automatic shuting is enable and the gate hits an obstacle, the
control panel will try to close the gate for max. 3 times then the gate will remain open, waiting for a START signal in order to close.