6.0 Technical Data

6.1

SPECIFICATIONS

Performance Data
Product Flow
Oxygen Delivery Pressure
Product Concentration
Product Dew Point
Dimensions (W x D x H)
(nominal)
Weight (without cover)
Physical Connections
Product Gas Outlet
Ambient Operating Conditions
Control Power Requirements
(Single Phase)
Typical Power Consumption
Compressed Air
Environment
SCF (Standard cubic foot) gas measured at 1 atmosphere and 70°F / Nm
1
at 1 atmosphere and 0°C / LPM (Liters per minute) gas measured at 1 atmosphere and 21°C.
*All performance ratings based on an ambient temperature up to 100°F (38°C), up to 1,000 feet elevation, and
80% relative humidity.
Workhorse-8 Instruction Manual
Workhorse-8
1
Table 6.1:
Workhorse-8 Specifications
8 SCFH (.21 Nm
/hr or 3.8 LPM)
3
9 psig (62 kPa or 0.62 barg)
90% +3%/-5%
-100°F (-73°C)
14 x 18 x 14 in (36 x 46 x 36 cm)
(maximum dimensions without cover)
43 lb (20 kg)
" FNPT
1
8
Locate the oxygen concentrator system in
a well-ventilated area that is protected from
weather elements and remains between
40°F (4°C) and 110ºF (43ºC) inside room or
operating enclosure; -20ºF (-29ºC) and 170ºF
(77ºC) in storage
120 V ~ ±10%, 60 Hz, 2.8 A
230 V ~ ±10%, 50 Hz, 1.8 A
230 V ~ ±10%, 60 Hz, 1.8 A
325 W
Pressure Relief Valve setting: 35 psig ±10%
Barometric Pressure Range: 28-31" of Hg
Ambient Oxygen Concentration: 20%
minimum
(Normal cubic meter) gas measured
3
AirSep Corporation