AMPY 5188A User Manual - Page 7

Browse online or download pdf User Manual for Measuring Instruments AMPY 5188A. AMPY 5188A 8 pages. Cardmeter

Cardmeter User Manual ver 008 2016-02-24.doc
5

RESET FUNCTION

5.1

Details

5.1.1
You will need to reset the meter if the meter has disconnected the supply
and locked out.
5.1.2
This will occur if a possible attempted fraud has been detected (the meter
will display LOCKED OUT), or of reverse running has been detected (the
display will flash RED meaning Reverse Running Detected).
5.1.3
The meter is reset by setting Rate 1 to 000.00ppu (see Setting Rates
example above), and then pressing the SETTINGS DISPLAY (blue button)
repeatedly until EC&DIS TO CLEAR is displayed. At this point, both
EMERGENCY CREDIT and SETTINGS DISPLAY buttons are pressed
simultaneously.
5.2

Other Parameters Reset

5.2.1
Emergency Credit Value
5.2.2
Emergency Credit Availability Point
5.2.3
Pence per kWh for all rates
5.2.4
Outstanding debt
5.2.5
Debt collection per week
5.2.6
Standing charge per week
5.2.7
Total cards
5.2.8
Total credit
5.2.9
Credit (debt)
5.2.10
Reverse running flag
5.2.11
After following this procedure, you will need to reset these registers to your
chosen values.
PAGE 13 of 16
Cardmeter User Manual ver 008 2016-02-24.doc
6

SPECIFICATION

6.1

Electrical Specification

Contactor rating
100A
Main Terminal diameter
8mm nominal
Auxillary terminal diameter
3mm nominal
Operating voltage
240V (+/-10%)
Frequency
50Hz
Current range
20A to 100A
Anticreep threshold (power)
12.5W (+/-20%) averaged during time
Anticreep threshold (time)
Existing below power threshold for 288 seconds
Indication
Pulse led permanently lit during anti-creep active
Deactivation
Exceeding average 12.5W for more than 288
seconds
PAGE 14 of 16