Comelit Icona 6601W/BM Technical Manual

Advanced configuration

If the basic configuration settings (A-P) do not reflect requirements, the buttons can be programmed differently by carrying out
the steps below.
After programming, set S2 DIP-switches 1-2-3-4 (PROG) to ON. With these DIP-switch settings, the buttons manage the
programmed functions.
The buttons that are NOT programmed control the functions in row A ("Basic configuration" table).

Intercom call

Introduction

By "General intercom call" we mean a call from a door-entry phone/door entry monitor to the devices (in the same apartment or
another apartment) identified by the call address for the apartment (user code).
By "Intercom call to selective address" we mean a call from a door-entry phone/door entry monitor to a device (or several)
identified by a specific (selective) address which is different from the call address for the apartment (user code).
General and selective intercom calls CANNOT be used together on the same riser!

General intercom call: button programming

1. Take note of the S1 DIP-switch settings.
2. To enter programming mode, set S2 DIP-switch 6 to ON.
» the LED
flashes
3. Refer to the table
"Basic configuration"
corresponding to the button you want to program appears, then set the S2 DIP-switches.
Example: For button 1= Intercom (INT) set S2 DIP-switches 1-2-3-4 as specified in row "C" in the "Basic configuration"
table.
4. Set the S1 DIP-switches according to the call address of the desired apartment. See
"Addressing table" on page 17
5. Press and release the button to be associated with the function.
» Correct procedure indication: the LED
√ when programming using several buttons, continue programming the next key by repeating the process from step 4
onwards.
6. Exit programming mode by setting S2 DIP-switch 6 to OFF.
» LED
switches off
7. Set S2 DIP-switches 1-2-3-4 to ON.
8. Return S1 DIP-switches to the original combination.
to identify a DIP-switch combination in which the intercom function (INT or INTb)
flashes for a few seconds and a confirmation tone sounds.
S2
S2
11