AMS AS5304 User Manual - Page 8
Browse online or download pdf User Manual for Accessories AMS AS5304. AMS AS5304 13 pages. Demo kit, 160-step linear incremental position sensor with abi output
AS5304 / AS5306 - Demo Kit User Manual
3. How to get the kit running
(1) Power up the demo board using the USB cable.
(2) During the start-up of the demo kit, a boot screen is shown offering basic information
about position sensor, firmware version and firmware release date. See
(3) After the start-up the position display is shown. The position display shows the actual
position counter value in steps and the calculated position in micrometer. Move the
multipole magnet slider. The position change is displayed. See
(4) Pull out the slider to remove the multi-pole magnet strip. At this point, the LEDs for
magnetic field strength and index will indicate a missing magnetic field.
(5) Fit the slider back into the mechanics. Press "Set Zero" to reset the position output.
(6) Unplug the USB cable to power down the board.
Figure 9:
Demo Kit Boot Screen
Figure 10:
Demo Kit Position Display
www.ams.com
Revision 1.3 / 09/24/12
Figure
9.
Figure
10.
Position Sensor
Firmware Version, Release Date
Counter Value
Calculated Position
Magnet Pole Pair Indicator Bar
page 7/13