Comelit KSW3207LU User Manual - Page 6

Browse online or download pdf User Manual for Switch Comelit KSW3207LU. Comelit KSW3207LU 19 pages. Wireless intruder alarm control panel
Also for Comelit KSW3207LU: User Manual (12 pages)

Comelit KSW3207LU User Manual
Custom area arming
This procedure is used to configure a custom arming program in which the user can quickly select the arming status for each area.
Access custom arming set with [CODE] + [ENTER]
Using buttons 1, 2, 3, 4 the user can set the desired arming status for each area (if present). An asterisk beside the arming status indicates that the setting has
been changed (but the areas are not in that condition yet)
The total arming button will then confirm the command.
10:30 15/11/2019
Dis Dis Dis Dis
Show open zones / faults
If there are open zones, the system will show "not ready to arm" and the green LED will flash. The "X" button will show the list of open zones, which will scroll
automatically (2 seconds for each zone). You can scroll through the list manually using the "Down arrow".
10:30 15/11/2019
Not ready to arm
Flashing
Show bypassed zones
You can check the list of bypassed zones by pressing Enter. You can scroll through the list using the "Down arrow".
10:30 15/11/2019
Not ready to arm
Flashing
System in alarm
In alarm condition, the type of alarm and the zone involved are shown. The red LED switches on.
If there is more than one alarm, you can scroll through them using the "Down arrow" (an arrow will appear on the right-hand side of the display to show that more
than one alarm is present).
Alarm:Burglary
Entrance door
6
Enter user code (default: 111111) 
10:30 15/11/2019
****--
Open z. 1/2
Entrance door
Bypassed zones:
Subj. window
Alarm:Burglary
Entrance PIR
User 1
Dis Dis Dis Dis
User 1
Arm* Dis Dis Dis
User 1
Arm* Dis Arm* Dis
User 1
Arm* Dis P1* Dis
User 1
Arm Dis P1 Dis
Open z. 2/2
Entrance PIR
2 Sec