AMS AS5 Series User Manual - Page 5

Browse online or download pdf User Manual for Adapter AMS AS5 Series. AMS AS5 Series 12 pages. Uart programmer
Also for AMS AS5 Series: Operation Manual (11 pages)

AMS AS5 Series User Manual
2.1

Mounting the AS5X47U Adapter Board

Figure 4 :
Mounting and Dimensions
A diametric magnetized magnet must be placed over or under the AS5x47U sensor, and should be
centered on the middle of the package with a tolerance of 0.5mm. The air gap between the magnet
surface and the package should be maintained in the range 0.5mm to 3mm. The magnet holder must
not be ferromagnetic. Materials as brass, copper, aluminum, stainless steel are the best choices to
make this part.
Demo Kit Manual • PUBLIC
UG000401 • v1-00 • 2018-Oct-31
Document Feedback
AS 5x47 U
22mm
5V
3V3
GN D
C S n
C L K
B
A
I/PW M
GN D
GN D
AS 5x 47 U
0.5-3mm
MOSI
MISO
GN D
W/PW M
V
U
4x2.6mm
AS5x47U Adapter Board
Board Description
│ 5
12