Browse online or download pdf Reference Manual for Controller AMS Controls MP328CL. AMS Controls MP328CL 17 pages. Closed loop backgauge controller
Program Mode
AMS Controls
5/23/2012
If the "Set Up" key is pressed twice, the following screen
appears:
1= Test Communications
2=Auto Calibrate
While in the second SETUP screen, pressing "1" will test the
communications with another controller if they are interfaced
together. If there is no communications, the messages "No Data
Received" and "No Data Sent" will be seen.
Pressing "2" while in the second SETUP screen allows the
controller to perform a calibration of the machine automatically.
If you enter a calibration value, the machine will move to that
point and prompt the operator for a measured value to that point.
The machine will then calculate the correction value and ask the
operator if they want this value updated.
(THIS MAY CHANGE!!)
The program mode is entered by pressing the "PRG" key. The
part "type" will start to flash, indicating that the controller is
waiting for the entry of the new type of part that is to be made.
The operator need only to press any number key to toggle
through the choices, and press the "ENT" key to lock the
selection in., the choices are:
-
Single Piece. Only the lip is bent, if programmed.
L
L-Shaped. Two bends are made (including the lip).
U
U-Shaped. Three bends (including the lip).
0
Full wrapper.
times (with the lip), to form a complete section of duct.
After the TYPE is selected, the HEIGHT and WIDTH
measurements can then be entered. Again use the "ENT" key to
lock the selection in. Only height will be used for (-) type parts.
PROGRAM SCREEN
S 0
Loc
Type : 0
12
One piece is made that is bent four
Bnd
0/3
50.00"
x
MP328CL Controller
0.00"
35.00"
Gripper