AMS Controls XL200 Series Specifications

Browse online or download pdf Specifications for Controller AMS Controls XL200 Series. AMS Controls XL200 Series 8 pages. Bar code scanner specifications
Also for AMS Controls XL200 Series: Battery Replacement Manual (5 pages), Battery Replacement Manual (8 pages), Battery Replacement Manual (8 pages)

Bar Code Scanner Specifications for
Scanner Specifications
Any scanner connected to an XL200 series controller must conform to the following communication
specifications:
Baud Rate: 9600
Stop Bits: 1
Parity: None
Data Bits: 8
Suffix: None (some scanners append a carriage return at the end of every scan by default)
DB9 Port
The DB9 port on the top of the XL200 controller has three uses:
Scanner port
Debug port
Flash memory port
DB9 Port Pinout
2
RS232 TX
3
RS232 RX
5
GND
7
RS232 CTS
8
RS232 RTS
Pin 7
Pin 7 of the DB9 port is the Clear-to-Send input on the controller.
A pull up resistor on that input keeps it high. In some RS232 applications, this input is toggled by the
outside device's Request-to-Send (called handshaking).
The XL200 controller does no handshaking, with either hardware or software, so it doesn't use pin 7
when communicating with other devices. However, a laptop connected to that port usually pulls pin 7
"low," which informs the controller to set up the port for a debug/flash.
XL200 Controllers
1