Dr. Clark VariZapper 2.0 Manual - Page 14

Browse online or download pdf Manual for Personal Care Products Dr. Clark VariZapper 2.0. Dr. Clark VariZapper 2.0 15 pages.

Dr. Clark VariZapper 2.0 Manual
The VariGamma 2.0

4.2.2 Battery charging

To recharge the battery, disconnect the VariGamma Module 2.0 and connect the VariCharger Module
EN
2.0 (Fig. 29). Attach the USB-C Charging Cable to the VariBase (Fig. 30) and connect it to a USB outlet
plug or a PC's USB port. The following image will be displayed (Fig. 31). Note that during the charging
phase ALL FUNCTIONS ARE DISABLED. A yellow LED light will light up on the VariCharger Module
2.0 while the device is being charged, the same LED light will blink when charging is completed (Fig.32).
The device will take a maximum of 3 hours to recharge completely. It is suggested to charge the device
only when neccessary (low battery), in order to maximize battery life.
Fig. 29
Fig. 30
Fig. 31
Fig. 32

5. Settings

Get to "Settings" from the Main Menu. Once you are in the Settings Menu, you have two choices (Fig. 33):
Fig. 33
Fig. 34
Fig. 35
Language: Press the Turnwheel button to select "Language". In the language Menu, choose your
language: English, German, French, Spanish or Italian (Fig. 34) and confirm/discard your choice.
Select
to go back to the previous menu or
to go back to the Main Menu.
Display and sound: Rotate the Turnwheel button to choose the menu Display/sound (Fig. 35). Select the
brightness or sound setting by pressing the Turnwheel button when on your choice. When the symbol
„<--->" appears, you can rotate the Turnwheel button to change the value of the brightness or sound. By
pressing the Turnwheel button again, you confirm the change. Select
to go back to settings or
to
go back to the Main Menu.

6. Care and cleaning

The VariGamma 2.0 requires no special maintenance or cleaning materials. The device may be
cleaned with a soft, lint-free cloth. Make sure no moisture gets inside the device. If moisture
does enter the case, a technical inspection is required before the device is used again.
Do not use any alcoholic or abrasive fluids.

7. Classification

The VariGamma 2.0 is not a medical device. Do not use it for any medical purpose.
The device is a Bio-Frequency Generator and can generate a signal as described in the books of Dr. Hul-
da Clark. Note that the frequency applications according to Dr. Hulda Clark have not yet been sufficiently
confirmed by clinical studies to allow any medical claims for this purpose. We specifically do not and are
not allowed to claim any medical purposes or benefits for the use of the device.
8. Saftey inspections
When used commercially or in business, safety inspections of the VariGamma 2.0 must be made after 24
months. The safety inspections must include:
1. Verification of the existence of the instruction manual
2. Verification of the completeness of all fittings
3. Visual examination
• for mechanical damage
• of all cables and connections for damage
4. Functional Safety
• Inspection of the signals generated
• Verification of the frequency
These technical inspections may only be made by specifically trained persons and must be documented.
14