Mach LED 115
Extent of supply
1x 5-footed plastic central base
2x extension arms with blocking rollers
2x extension arms with electrically conductive rollers
1x extension arm with roller
1x cam catch plate
1x cheese head screw M8 with lock washer
1x stand tube
Lamp head with arm
Mounting instructions/Instructions for use – lamp head and stand
2.1 Mounting the mobile stand
1
11
10
6
13
3
4
59060001
2. Mounting instructions
2
8
9
7
14
5
12
Edition 01
For mounting the stand proceed as follows:
Place the central base 1 onto the stand
tube 25 2. The stiffness is to ensure a
tight fit that is free from any movement.
Pre-mount the cam catch plate 3 (cams
point inwards), with the lock washer 4 and
cheese head screw M8 5, so that the ex-
tension arm 6 can still fit easily into the
central base. Insert the extension arm 6 in-
to the central base from above holding the
cam catch plate 3 against from the oppo-
site side.
Insert the other 4 extension arms 7-10 in
the sequence shown in the left figure into
the central base. The extension arms are
held by the cams of the cam catch plates.
Remark: Mount the two locking rollers 11
and 12, and the two electrically conductive
rollers 13 and 14 as shown in the figure (not
next to each other).
Tighten the catch plate with an Allen key
SW6 (approx. 15Nm).
The cams of the catch plate must mate with
the drill holes of the extension arms so that
every extension arm is tightly fitted to both
the central base and stand tube.
The cams also prevent the extension arms
from being pulled out.
02.08.2012 / Bak Page 4/15
Dr. Mach