Electrolux CARAVAN AES II RM 6505 User Manual - Page 8

Browse online or download pdf User Manual for Refrigerator Electrolux CARAVAN AES II RM 6505. Electrolux CARAVAN AES II RM 6505 11 pages.

Electrolux CARAVAN AES II RM 6505 User Manual
Cut out opening for the
side vent L500
is 341 x 451 mm.
L205 is 156 x 451 mm.
min. ventilation
height
Cut out opening for the
side vent L500
is 341 x 451 mm
40
Batten
attached to
the floor
FIG. 3a
20
Removal of flue gases
The ventilation passage at the rear of the recess, be-
tween the outer wall of the motorhome and the refrig-
erator (fig. 3a/b/c), must be sealed off against the living
space, so cold draughts are excluded (winter camping)
and no flue gases can penetrate into the motorhome.
The flue gases are dispersed through the upper vent
grille or the roof vent together with the ventilation air.
The top, bottom and sides of the ventilation passage
should be insulated to prevent condensation and cold
draughts.
Ventilation heights
Minimum ventilation heights in mm.
Model
Upper side vent L205
Lower side vent L500
RM 6505
1400
VENTILATION OF THE UNIT
Sealing gasket
e.g. of V-type
This piece is
already on the
60
refrigerator
Condenser
385
min. 510
Sealing gasket
e.g. of V-type
Floor
Installation with
Upper side vent L500
Roof vent R500
Lower side vent L500
Lower side vent L500
1400
1250
Cut out opening for the
roof vent R500
is 87 x 507 mm
min. ventilation
height
Cut out opening for the
side vent L500
is 341 x 451 mm
FIG. 3b
20
Batten attached
to the side wall
FIG. 3c

LP GAS CONNECTION

The refrigerator is designed for operation on LP gas, the
pressure of which must be 28 mbar for Butane and 37 mbar
for Propane. Check that this is stated on the data plate.
The refrigerator is not designed for operation on
town gas or natural gas.
Condenser
min. 510
Sealing gasket
e.g. of V-type
View from above
Door
17