7.1.2.

CCID Bulk-IN Messages

The Bulk-IN messages are used in response to the Bulk-OUT messages. ACR100I shall follow the
CCID Bulk-IN Messages as specified in CCID Section 4. This section lists the CCID Bulk-IN
messages to be supported by ACR100I.
7.1.2.1.
RDR_to_PC_DataBlock
This message is sent by ACR100I in response to PC_to_RDR_IccPowerOn, PC_to_RDR_XfrBlock
and PC_to_RDR_Secure messages.
Offset
0
bMessageType
1
5
6
7
8
9
bChainParameter
10
7.1.2.2.
RDR_to_PC_SlotStatus
This message is sent by ACR100I in response to PC_to_RDR_IccPowerOff,
PC_to_RDR_GetSlotStatus, PC_to_RDR_Abort messages and class specific ABORT request.
Offset
0
bMessageType
1
5
6
7
8
9
bClockStatus
ACR100I – Reference Manual
Version 1.00
Field
Size
1
dwLength
4
bSlot
1
bSeq
1
bStatus
1
bError
1
1
Byte
AbData
array
Field
Size
1
dwLength
4
bSlot
1
bSeq
1
bStatus
1
bError
1
1
Value
Description
Indicates that a data block is being sent
80h
from the CCID
Size of extra bytes of this message
Same value as in Bulk-OUT message
Same value as in Bulk-OUT message
Slot status register as defined in CCID
Section 4.2.1
Slot error register as defined in CCID
Section 4.2.1 and its specifications in
Section 5.2.8
00h
RFU (TPDU exchange level)
This field contains the data returned
by the CCID
Value
Description
81h
00000000h
Size of extra bytes of this message
Same value as in Bulk-OUT message
Same value as in Bulk-OUT message
Slot status register as defined in
CCID Section 4.2.1
Slot error register as defined in CCID
Section 4.2.1 and its specifications in
Section 5.2.8
Value =
00h Clock running
01h Clock stopped in state L
02h Clock stopped in state H
03h Clock stopped in an unknown
state
All other values are RFU.