DRAKE PS7 1502 Instruction Manual - Page 5

Browse online or download pdf Instruction Manual for Power Supply DRAKE PS7 1502. DRAKE PS7 1502 9 pages.

Overvoltage Protection

If the PS-7 regulator section should fail or one of the pass tran-
sistors should short, the unit will automatically shut down. If the
DC output voltage should soar above 16 VDC, an SCR crowbar
clamps the output to ground to protect the load and open the pri-
mary fuse. This fuse should b e replaced with another of the same
type and rating after determining the cause of the overload.

Line Voltage Programming

The PS-7 comes factory set for 120 VAC 50-60 Hz operation. To
change the primary input range, simply remove the four screws
holding the programming plate. Refer to Figure 2. As an example,
suppose the line voltage measured 200 VAC. Remove the plate
and slide the voltage switch to 200/240. Then slide the HI/LO
switch to LO. Rotate the plate until 200 shows up in the window
and the LO switch fits through its locator hole. Reinstall the four
screws. If 200 or 240 VAC operation is desired, he sure to replace
the fuse with a 4 amperc type M TH fuse.
Fig. 2-PS-7 Line Voltage Programming
100
200
Hi
Lo
Lo
Hi
100
Hi
Lo
200 P 240
100
200 cl 240
Hi
Lo
120
120vac +-lO% 50-60 Hz
Range:108-132vac
240
1OOvac +-lO% 50-60 Hz
Range:90-110vac
240vac +-l0% 50-60 Hz
120
Range:216-264vac
120
200vac +-lO% 50-60Hz
Range:180-220vac
4
1 0 - 8 - 7 9