Bosch FAP-OC 500Series Installation Manual - Page 13

Browse online or download pdf Installation Manual for Washer Bosch FAP-OC 500Series. Bosch FAP-OC 500Series 32 pages. Built-in wall ovens
Also for Bosch FAP-OC 500Series: Installation Instructions Manual (21 pages), Instructions For Use Manual (40 pages), Installation Manual (6 pages), Product Information (40 pages), Installation Manual (28 pages), User Manual (48 pages), User Manual (48 pages), Installation Manual (28 pages), Use And Care Manual (44 pages), Installation Manual (32 pages), Use And Care Manual / Installation Instructions (40 pages), Quick Reference Manual (4 pages), Use And Care Manual (27 pages), Installation Manual (24 pages), Installation Manual (32 pages), Use And Care Manual (24 pages), Installation Manual (28 pages), Service Manual (41 pages), Use And Care Manual (21 pages), Service Manual (36 pages), Installation Manual (32 pages), Quick Start And Safety Manual (13 pages)

Bosch FAP-OC 500Series Installation Manual
Lift the microwave, tilt it forward, and hook slots at
1.
back bottom edge onto four lower tabs of the
mounting plate.
Rotate the front of the oven up against cabinet bottom.
2.
Insert a self-aligning screw (item A) through top center
3.
cabinet hole. Temporarily secure the oven by turning
the screw at least two full turns after the threads have
engaged.
Insert the two remaining self-aligning screws through
4.
outer top cabinet holes. Turn two full turns on each
screw.
Tighten center screw completely.
5.
Tighten the outer two screws completely to the top of
6.
the microwave oven.
Note: While tightening screws, hold the microwave
oven in place against the wall and the top cabinet.
Install grease filters by sliding them into the side slots,
7.
then pushing up and toward oven to lock (image
shows bottom view of appliance).

Hood exhaust

When venting exhaust to the outside, hood exhaust ducts
will be required. Read the following carefully.
Note: It is important that venting be installed using the
most direct route and with as few elbows as possible.
This ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely and
nothing is blocking the ducts.
The hood exhaust has been designed to mate with a
standard 3¼" x 10" (82 x 254 mm) rectangular duct. If a
round duct is required, a rectangular-to-round transition
adaptor must be used. Do not use less than a 6"
(152 mm) diameter duct.
For satisfactory air movement, the total duct length of
3¼" x 10" (82 x 254 mm) rectangular or 6" (152 mm)
diameter round should not exceed 120 equivalent feet
(36.5 m).
Elbows, transitions, wall and roof caps etc. cause
additional resistance to airflow and are equivalent to a
section of straight duct which is longer than their actual
physical size. When calculating the total duct length, add
the equivalent lengths of all transitions and adaptors plus
the length of all straight duct sections. The chart below
shows you how to calculate total equivalent ductwork
length using the approximate feet of equivalent length of
some typical ducts:
13