Access FIT E and V
Section 8 - Limit Adjustments
Figure 9
Please Note: Screen limits are
factory set. Instructions below
for minor adjustments only.
Please check with Draper prior
to resetting screen limits.
Please Note: If Access screen
is "Right Hand Motor" or
"Waterfall," the WHITE/DOWN
and YELLOW/UP
limit
(I)
(II)
screws are reversed
.
(Fig. 10)
CAUTION:
- Be sure all switches are in "off"
position before adjusting limit
switches.
- Be prepared to shut off manually
while testing.
Figure 10
Motor
Motor
End
End
e
n c
d i e
e
A u
S i d
Standard Roll
Reverse Roll
Left hand motor:
Left hand motor:
White Socket—Down
White Socket—Down
Yellow Socket—Up
Yellow Socket—Up
Right hand motor:
Right hand motor:
White Socket—Up
White Socket—Up
Yellow Socket—Down
Yellow Socket—Down
Section 8.2 - ILT Motors with Internal Low-Voltage Control Limit Adjustments
Please Note: Hold STOP button for 3-5 seconds while in
programming mode to reverse motor direction.
Figure 11
BACK VIEW OF WALL SWITCH
To Motor
with
Internal
Low Voltage
Slide
Switch
C
o
m
+
m
5V
o
To Motor
DC
n
with
Internal
Low Voltage
POSITION
FUNCTION
DOWN
Set LOWER limit
UP
Set UPPER limit
CENTER
Normal Operation
Please Note: 5V DC must be connected to
be able to set limits using the wall switch.
DOWN Limit
DOWN Limit (I)
+
Clockwise
I
Clockwise decreases
decreases
down travel.
down travel.
UP Limit (II)
+
lI
UP Limit
Counterclockwise
(II)
Counterclockwise
increases up travel.
increases up travel.
- Screen may be damaged by
lowering it too far and
exposing roller.
- Motor must be installed so that
limit switches are pointed down.
Motor
End
n c
d i e
c k
e
A u
B a
S i d
d e
S i
Waterfall Roll
Left hand motor:
White Socket—Up
Yellow Socket—Down
Right hand motor:
White Socket—Down
Yellow Socket—Up
Please Note: When ordering a motor with internal low-voltage controller, if case ships
1. Connect ILT switch to motor via terminal blocks, or via
modular port using a four conductor modular cable. When
using modular cable, cable connectors MUST NOT be
crimped in reverse, as with standard telephone cable.
(For Dry Contacts Wiring Diagram, see Section 12.)
2. Set slide switch to lower position. Hold DOWN button to
move viewing surface to desired lower limit. If screen moves
in opposite direction, release DOWN button and hold STOP
button for 4 seconds. This reverses operation of UP and
DOWN switches.
3. Move slide switch into center position. Wait several seconds.
D
o
U
Please Note: Do Not move slide switch from DOWN to UP
w
p
n
in one motion. This will set limits in same position.
4. Set slide switch to higher position. Move viewing surface to
desired upper limit by holding UP button on wall switch.
5. Return slide switch to center position to resume normal
operation.
6. To set viewing surface to alternate format position, move
viewing surface to desired position and press STOP button.
Hold STOP button for at least 3 seconds to record position.
Section 8.1 - Somfy Motors Limit Adjustments
:
(I)
Section 8.1.1 - "Down" Limit Adjustment
To Reduce Screen Drop:
1. Raise screen surface approximately 1'
turn off.
2. Turn DOWN
(I)
3. Test by lowering screen. Repeat steps 1 & 2 until desired position is
reached.
:
To Increase Screen Drop:
1. Lower screen to down limit.
2. With down switch on, turn DOWN
(3 screw turns = 1/2 roller revolution)
3. Test by raising screen approximately 1'
down limit.
4. Repeat steps 2 and 3 until desired position reached.
Please Note: For Quiet Motor with alternate limit screws:
WHITE screw = UP and RED screw = DOWN.
However, limits are reversed if surface is waterfall rolled
Section 8.1.2 - "Up" Limit Adjustment
If Screen Raises Too High:
1. Lower screen surface approx. 1'
e
2. Turn UP
limit screw clockwise
(II)
3. Test by advancing screen up.
4. Repeat steps 1 through 3 until desired position is reached.
If Screen Needs to Raise Higher:
1. Lower screen surface approx. 1'
2. With UP switch on, turn UP
(3 screw turns = 1/2 roller revolution)
3. Repeat steps 1 and 2 until desired position is reached.
CAUTION: DO NOT allow dowel to wrap over roller when operating screen!
This could damage screen.
(Fig. 11)
separate from "guts," it includes 25'
(Fig. 9)
(requires 5/32" (4 mm) Allen wrench)
above desired setting and
(30 cm)
limit screw clockwise
(3 screw turns = 1/2 roller revolution)
limit screw counterclockwise
(I)
to increase drop.
then down to new
(30 cm)
below desired setting and turn off.
(30 cm)
(3 screw turns = 1/2 roller revolution).
below desired setting and turn off.
(30 cm)
limit screw counterclockwise
(II)
.
cable and special low-voltage switch.
(7.6 m)
Please Note: Press and release UP
button on switch to move screen to
upper limit. Press and release DOWN
button to move screen to lower limit.
• While motor is in motion, press
STOP button for less than 2
seconds to stop viewing surface at
present position.
• Once motor is stopped, press
STOP button to move viewing
surface to alternate format position.
• Hold STOP button, when motor is
at rest or in motion, for 3-5
seconds to record new alternate
format position.
• Hold STOP button for 3-5 seconds
while in programming mode to
reverse motor direction.
page 6 of 8
.
.