Draper Paragon Specifications - Page 2

Browse online or download pdf Specifications for Projection Screen Draper Paragon. Draper Paragon 2 pages. 220v electric screen
Also for Draper Paragon: Installation And Operating Instructions (2 pages), Installation & Operating Instructions (2 pages), Installation & Operating Instructions (2 pages)

Draper Paragon Specifications
Paragon by Draper
Optional Wall Mounting Bracket
1"
7
2
/
"
8
1
3
/
"
4
7
2
/
"
8
1
3
/
"
4
7
2
/
"
8
1
/
" dia.
2
3
/
" dia.
8
*Please Note: Optional wall brackets add 1¾" per bracket to case length. Wall mounting bracket hole location is 1" from end of case.
* For more information and wiring diagrams for low voltage
multiple motors and network communication, please see
Draper Screen and Lift Controls Planning Sheet, Draper
Screens and Lift Controls Wiring Manual and wiring
diagrams supplied with individual items.
Case Dimensions*
12"
1
13
/
"
4
2¼"
2"
2"
Wiring Diagrams
Single Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Dashed wiring
by electrician
Control
Single gang box by others
switch
1
7
Min. 4" x 2
/
" x 1
8
Red
Blue
Black
Location of key
operated on-off
switch if furnished
To 110-120V Line
Low Voltage, IR Remote or RF Remote (LVC-III)
www.draperinc.com
*
* - Case support brackets will be evenly spaced along the case
8"
2"
3
1
/
"
8
2¼"
5"
Multiple Station Control
Internal Screen Wiring
White (Common)
Black (Down)
Red (Up)
Green (Ground)
Cap off with wire
nut and tape
Red
Blue
/
" deep
8
Black
Red
Blue
Black
Red
Blue
Single gang box by others
Black
Min. 4" x 2
3 shown. More or less equally
feasible.
Location of key
operated on-off
switch if furnished
To 110-120V Line
White-Common to screen & 110-120V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 110-120V AC-Hot
Black-to 110-120V AC-Hot
Green-Ground
Dashed wiring by electrician
Low voltage wiring by others
Eye Port for IR Eye, RF Receiver or LED
Wall Switch. For more than one of
these, a splitter is required.
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Aux Port for connecting additional LVC-III
modules (up to six total can be linked-
connect from Aux to Eye).
PROJECT:
SUPPLIER:
DATE:
(765) 987-7999
Dashed wiring
by electrician
1
7
/
" x 1
/
" deep.
8
8
Internal Screen Wiring
White (Common)
Red (Up)
Black (Down)
Green (Ground)
To
110-120V
Line
STOP
Location of key
operated on-off
switch if furnished
STOP
Control
Switches
24v DC
REVISED:
Page 2 of 2