Draper SLX14 Installation & Operation Instructions - Page 7
Browse online or download pdf Installation & Operation Instructions for Projection Screen Draper SLX14. Draper SLX14 8 pages. 230v ac scissor lift slx video projector lift
Also for Draper SLX14: Brochure & Specs (16 pages), Installation And Operation Manual (7 pages), Installation & Operating Instructions Manual (7 pages), Installation & Operating Instructions (4 pages), Installation & Operating Instructions Manual (7 pages)
Scissor Lift - SLX 115V
Section 11 - Electrical Connections
Lift operates on 115V, 60 Hz. current. 14 amps current draw
Wire to connect lift to switch
and switch
(es)
Please Note: Lift must be installed in accordance with requirements of Local Building Codes, Canadian Electrical Code
Code
, NFPA 70. An appropriate disconnect device shall be provided as part of building installation.
(NEC)
CAUTION: All operating switches should be "off" before power is connected.
A junction box is provided for field connections. Unit ships with internal lift wiring complete. Use switch to lower lift and remove packing. Remove temporary wiring and
complete permanent wiring to electricity and to switches. Wire to connect unit to power supply and to switches should be furnished by installer. Connections should be
made in accordance with wiring diagram. Lift should be operated and checked prior to installing projector and/or optional ceiling closure.
Section 12 - Wiring Schematic
GN/YL
IR EYE
WH
RD
WH
BK
ENCODER CABLE
RF
PAIRING
V in
RD
A
RD
WH
+
B
WH
-
GND
BK
ENCODER CABLE
Section 13 - RS232 and RS485 Serial Port Protocols
Sending Lift Commands
START
ADDRESS
1 Char
2 Chars
XX
L
XX = Decimal motor group address with range from 01 to 32.
Note it always has to be 2 characters,
so a 0 has to precede 1 digit addresses.
YYYYYY
= command from the following table:
EXAMPLES:
COMMAND
ACTION
L01R!
Move
Channel 1
L11E!
Move
Channel 11
(2 amps for lift, 12 amps for Outlet)
to power supply should be furnished by installer.
(es)
2 CONDUCTOR CABLES
ATTACHED TO
REAR SCISSOR
DOWN
Limit Switch
NC
BN
BK
RD
WH
BK
YL
MODE
SWITCH
UP
Limit Switch
RD
NC
OR
BK
NC
BK
RD
RD
A
WH
B
BK
GND
115Vac, 12A
50-60 Hz OUTLET
NOTES:
1. When the Optional Delay Feature is installed the Delay Switch must
be in the "Delay On" position for normal operation.
2. If the Optional Delay Feature is installed and the "Show" position requires adjusting
the "Delay Switch" must be switched to "Off" while adjusting the show position
3. Refer to the "Adjusting" section on page 4 of these instructions
for information on how to adjust the "Show" position.
WH
RD
BK
COMMAND
END
1 - 6 Chars
1 Char
YYYYYY
!
COM Port Settings:
Port Speed:
Data Bits
to Fully
Retracted.
Parity
to Fully
Extended.
Stop Bits
Flow Control
Lift ships with internal wiring complete and control switch
BK
BK
WH
OR
RD
MOTOR
BK
DOWN
Delay Switch
RUN CAP
45 MFD
BL
(on position)
UP
RD
RD
OR
RD
GN/YL
BK
BK
BK
WH
WH
BK
Dashed wiring by electrician
Low voltage wiring by others
ENCODER
9600 baud
8
NONE
1
X On / X Off
, CAN/CSA C22.1 and National Electric
(CEC)
BK
BK
WH
OR
RD
Attached to
Optional Delay Assembly
lower pan
N
WH
115VAC
ALTERNATE 'UP' LIMIT SWITCH WIRING
BK
Power Supply
GN
*Black
Jumper wire is located in the
(BK)
plastic sleeve with these instructions.
NOTE : Jumper CANNOT be used when lift
is installed in Environmental Air Space
Housing and Optional Ceiling Closure
COMMAND
E
FULLY EXTEND
R
FULLY RETRACT
S
STOP
SP1
Go to FIRST show position
SP2
Go to SECOND show position
P
PREVIOUS show position
N
NEXT show position
ADD show position
ADDSP
DELETE show position
DELSP
ID
Identify channel
SET
SET splitter board channel
ADD
ADD a communication channel
DEL
DELETE a communication channel
FS1
Restore MAIN BOARD to Factory Settings
FS2
Restore SPLITTER BOARD to Factory Settings
FS0
TILT to PREVIOUS STOP
GETFV1
Get MAIN BOARD Firmware Version Number
GETFV2
Get SPLITTER BOARD Firmware Version Number
page 7 of 8
fully boxed.
(es)
AC
BK
AC
WH
RD
COM
N.O.
OR
N.C.
Up
Limit
Switch
RD
OR
NC
NC
BK
BK
BK
Jumper*
ACTION
(Setting main board)
(Setting main board)