OPERATION Cont'd

4. To start the compressor turn the switch to the
ON position as shown in Fig.4.
The pressure switch is pre-set at the factory and
the compressor is also fitted with an overload
safety relief valve in the event of the pressure
switch not functioning correctly.
5. To stop the compressor turn the pressure switch
to the OFF position. Do not switch off at the
power supply before switching off at the
machine. See Fig.5.
The amount of air pressure inside the receiver
is indicated by the gauge ✭✌ Fig.5.

MAINTENANCE

IMPORTANT:
Before performing any maintenance operations,
disconnect the compressor from the power supply
and release all the air from the receiver, until the
pressure gauge reads zero.
EVERY DAY:
A. Check the oil level and top up if required with
Shell Corena P68 Monograde oil or equivalent.
B. Drain the condensate from the receiver. The
drain plug ✮✌ Fig. 6. is situated on the
underside of the receiver tank.
EVERY MONTH:
A. Clean the air suction filter using compressed
air. Replace the filter every 500 hours of use.
NOTE:- The position of the filter will vary on
each model, refer to the parts listing & drawing
of the model concerned.
B. Check the tension of the drive belt and adjust if
necessary.
EVERY 1000 HOURS:
A. Replace the oil. Remove the drain plug ✯✌
Fig.7. and drain the oil into a suitable container.
Refit the drain plug and refill the crank case
with new oil to the correct level.
B. Clean all the external surfaces of the pump unit
and motor. Ensure that neither the motor fan
cowling ✰✌ or head cooling fins ✱✌ are
blocked or obstructed in any way. See Fig.8.
EVERY 2000 HOURS:
Check the condition of the valves and replace
✮✌