8. Wind the Draw Cable 1-2 turns around the Cable Spool
at each end of the roller assembly.
9. Insert the Draw Cable through the Cable Spool and
Cable Clamp at each end of the assembly
10. Pull slightly on the Draw Cable to ensure that the Cable
Clamp has secured the Draw Cable.
11. Tighten the Draw Cable by pulling it through one of the
Cable Clamps.
12. Ensure the Draw Cable is routed properly around the
pulleys inside the Hem Bar assembly, as well as around
the pulleys in the Mounting Brackets
13. Cut off the excess Draw Cable for each end of the Roller
Assembly. Insert the Tensioning Tool into the Spring
Cassette Cable Spool and tension the shade 10-20
turns
.
(Fig. 9)
14. Set the Motor limits so that the shade stops about ½"
away from the Mounting Brackets at both ends
(13 mm)
of shade travel
(see "Limit Setting" section)
Caution: Allowing the Hem Bar to run into the Brackets
may result in damage to the unit. Ensure that the pinch
points between the Bracket and Hem Bar are clear
during operation.
15. Cycle the unit and make sure the Hem Bar does not
contact the Draw Cable during operation. If it does, then
more tension is required in the Guide Cable. If required,
retract the Tensioner, loosen the Nut, pull more of the
Guide Cable through the Tensioner, re-tighten the Nut,
and extend the Tensioner. Repeat as needed until the
Hem Bar does not contact the Draw Cable.
16. After confirming that the Hem Bar does not contact
the Draw Cable and that the installation is complete,
shorten the Guide Cables
(Fig. 10)
Caution: Once the Guide Cables are shortened, they
may need to be replaced if more tension is needed.
C016.085
Cable Clamp
.
(Fig. 7)
Orientation
is CRITICAL.
Figure 7
.
(Fig. 8)
.
Figure 10
.
®
Left-Hand Cable Spool
Trim excess cable
exiting the spool.
Fabric Panel
Draw Cable Insertion:
1-2 wraps around spool
Figure 9
Right-Hand Cable Spool
Trim excess cable
exiting the spool.
Fabric Panel
Draw Cable Insertion:
1-2 wraps around spool
Figure 8
page 5 of 8
C016.085
Cable Clamp
Orientation
is CRITICAL.