Also for Bosch 800 Series: Installation Instructions Manual (24 pages), Installation Manual (40 pages), Use And Care Manual (12 pages), Installation Manual (23 pages), Installation Manual (28 pages), Installation Manual (32 pages), Instruction Manual (32 pages), Installation Manual (32 pages), Quick Start And Safety Manual (7 pages), Use And Care Manual (40 pages), Installation Manual (40 pages), Installation Manual (32 pages), Installation Manual (48 pages), Use And Care Manual (33 pages), Use And Care Manual (49 pages), Quick Start Manual (7 pages), Quick Start And Safety Manual (13 pages), Installation Manual (32 pages), Service Manual (36 pages), Installation Instructions Manual (29 pages), Use And Care Manual (24 pages), Use And Care Manual (40 pages), Installation Instructions Manual (28 pages)

Bosch 800 Series Installation Instructions Manual

Mounting the back-pressure flap

Using 4 screws (4x8 mm), attach the back-pressure flap
to the extractor hood.
Connecting the air extractor (only for
ducted operation)
Note: If an aluminum pipe is used, smooth the
connection area beforehand.
1.
Attach exhaust air pipe and seal.
Check whether the back-pressure flap works.
2.
Mounting the recirculation model (only for
circulating-air mode)
1.
Use 4 screws (4x8 mm) to screw the housing to the
angle bracket.
A
Screws
B
Recirculation module
C
Angle bracket
2.
Measure the distance (x) between the bottom edge of
the housing for the recirculation module and the
bottom edge of the back-pressure flap.
A
Recirculation module
B
Clamps
C
Flue duct
D
Exhaust air duct
Shorten the exhaust air pipe to the length measured.
3.
4.
Remove the recirculation module.
5.
Push the exhaust air pipe onto the bottom side of the
recirculation module.
Position the recirculation module with exhaust air pipe
6.
over the air extraction duct of the extractor hood.
Use 4 screws to fasten the recirculation module to the
7.
angle bracket.
Secure connections with clamps.
8.
11